FEED ANALYZER

N-SENS Online

Optimizing efficiency and profitability in production processes is achieved through process control. N-SENS ONLINE is a system based on near infrared spectroscopy that enables direct visualization of analysis parameters in process control systems.

N-SENS ONLINE

 

N-SENS ONLINE enables continuous analysis and monitoring of raw materials and finished products entering the production process. The system can be easily integrated into the automation panel of process lines and ensures the prevention of production errors.

Wavelength Range

The N-SENS ONLINE NIR analyzer operates in the wavelength range 950-1650 nm and measures 2000 spectra/sample per sample.

 

Quality Sensors

It performs higher quality and precise analysis with its high sensitivity and 23 thousand signal-to-noise ratio sensor.

Durable

Thanks to its stainless steel housing and 3mm sapphire process line interface, it is easy to install and resistant to adverse production conditions.

Cost Effectiveness

It enables analyzes to be performed at more affordable costs.

Correct Analyses

It enables the analysis of organic and inorganic parameters in all raw materials and finished products.

Environmentally Friendly

It provides non-destructive and environmentally friendly analysis with minimum sample quantity.

Saving Time

Together with the optimization of the analysis time, it will save the plant’s time.

ENVIRONMENTAL CONDITIONS
Operation Range 0 – +35°С (Humidity ≤ 85% at 35°С)
Storage and Transportation Range -20 – +40°С (Humidity ≤ 85% at 40°С)
Mechanical Environment Process Control
DEGREE OF PROTECTION
IP Protection Class IP65
INTERFACE CONNECTION
Ethernet High quality, Shielded LAN cable, Min. Category 5e RJ45 (IP 67) LAN Connection
ADAPTOR
Adapter Specifications 2.1 Plug-in
Adapter Input Voltage 176-264 V
Adapter Frequency 50/60 Hz
Adapter Output Voltage 24 V DC
Adapter Output Current 3.6 A
DIMENSIONS
Diameter 96 mm
Length 180mm
PROCESS LINE INTERFACE
Sapphire Diameter 35/25 mm, Thickness 3mm, with Food Grade O-ring Gasket
MATERIAL
Gövde Stainless Steel 316
ANALYSIS FREQUENCY
Real Time Ort. 2-20 sec./analysis
TECHNOLOGY
Method Near Infrared spectroscopy (NIR)
SOFTWARE
Software ProChem
SPECTRAL PROPERTIES
Wavelength Range 950 – 1650 nm (10,526 – 6060 cm-1)
Spectral Bandwidth <1.25% of center wavelength (1% typical)
Detector InGaAs photodiode array
Dynamic Range (Max) 1000:1
Integration Time 10 ms typical, minimum 10 µsec
Signal-to-Noise Ratio (Typical) 23,000 (average 100 scans)
Number of Measurements 2000 spectra/sample
Lamp Life >10,000 hr
Reference Spectralon (>99% Diffuse Reflectance)
Absorbance range Up to 3 AU
ANALYSIS FEATURES
Analysis Time <30 seconds*
Sample Type Direct measurement of solid and liquid samples in ground or unground state
Parameters Moisture, Crude Protein, Crude Fat, Crude Ash, Crude Cellulose and Starch

N-SENS GENERAL FEATURES

 

N-SENS ONLINE The calibration line is created specifically for the process line with the analyzes performed in the fully equipped food and feed analysis laboratory within Nutrilab. Thanks to the calibration models created specifically for the process line, raw materials or finished products are analyzed quickly and accurately at the time of production, thus optimizing the efficiency of the process line.

Corn

Soybean Meal

Sunflower Seed Meal

Wheat

Ruminant Feed

Chicken Feed